Last week I wrote a blog about the most common places to find gas leaks, and I said I'd follow up with a blog about gas connectors - those short, flexible, corrugated things that are used to connect gas appliances to gas piping. Today I'll go over the items that I look for on gas connectors while doing home inspections. I'll cover the most common installation defects, and I'll go over the differences between new and old connectors.

Gas Connectors are not a substitute for gas piping. To start, here's a photo of a gas connector - it's that corrugated yellow thingy. Most newer gas connectors look just like this one. A gas connector is used to get from the gas piping to the appliance - that's all. Gas connectors should never be used as a substitute for gas piping. This means that if you ever see two connectors joined together, it's an improper installation. This material is not a flexible gas line. It's a gas connector.
Gas Connectors should never disappear in to a concealed location. If a gas connector disappears in to a wall, floor, ceiling, or cabinet of an appliance, it's an improper installation. Only proper gas piping should be run through walls, floors, cabinets, etc.


Gas Connectors need to be sized appropriately. I stopped by my favorite orange box the other day to check out their selection of gas connectors, and they had three sizes available - low demand, moderate demand, and large demand connectors. It's alright to go larger, but not smaller. The size and length of the appliance connector is determined by the BTU rating of the appliance. Most jurisdictions allow six foot connectors for ranges and clothes dryers, and three foot connectors for everything else.

Old Gas Connectors should be replaced. The current standard for gas appliance connectors is ANSI Z21.24. I tried to get a copy of those standards for this blog so I could say what what makes the newer connectors different, but it would have cost me almost $600 (get out of here), so I did something even better. I got my hands on a new gas connector and an old one, and I cut 'em open. Here's what I found.

As you can see, they're made from different materials. The new gas connector, which complies with ASNI Z21.24, is made from stainless steel. The old connector obviously isn't - it's made from brass, or so I've been told.
To quickly spot the difference between the old and new connectors, you can usually just look at the outside jacket. Old connectors will typically have a grey coating, like the one shown above left, a braided stainless steel jacket like the type shown below, or they'll obviously be made of uncoated brass like the one shown far below.