How to Fill Missing Knockouts in Electric Boxes

One of the most common Truth-in-Housing repair items is an unfilled opening in an electrical box or panelboard. If you walk through the garage or basement of just about any old Minneapolis or Saint Paul home, you'll probably find a few of these.

By hominspector

March 13, 2013 at 7:16PM

One of the most common Truth-in-Housing repair items is an unfilled opening in an electrical box or panelboard. If you walk through the garage or basement of just about any old Minneapolis or Saint Paul home, you'll probably find a few of these.

(The Minnesota Star Tribune)
(The Minnesota Star Tribune)

The national electric code says that unused openings in such equipment need to be closed. Covering these openings helps to prevent accidental shocks (think of kids), helps to prevent hot sparks from escaping if something goes wrong inside the enclosure, and helps to prevent pests from entering. It happens.

(The Minnesota Star Tribune)

How to fix a missing knockout plug

First, determine the size of the missing knockout hole and subtract 3/8" to figure out what size knockout plug you'll need. For example, if you have a 7/8" hole, you'll need a 1/2" knockout plug. Next, go buy some knockout plugs. They're sold in small quantities at hardware stores and home improvement stores for about a quarter each.

(The Minnesota Star Tribune)

Next, kill the power to any circuits going through the box you're working on. As GI Joe always thought to himself, "being safe is the other half." Finally, put the plug in the hole. If you bought the right size, it will be nearly impossible to push the plug in to place with just your hands - you'll need to tap the plug in to place using a hammer.

(The Minnesota Star Tribune)
(The Minnesota Star Tribune)

If you want to make the plug super tight and impossible to remove, you could bend the tabs inside the box with a screwdriver. I'm sure some electricians would say this should always be done. The photo below left shows the tabs in their normal position, and the photo below right shows the tabs bent out.

(The Minnesota Star Tribune)
(The Minnesota Star Tribune)

For Truth-in-Housing evaluations, missing knockout plugs are required repair items in Bloomington, Hopkins, Robbinsdale, and South Saint Paul. They're considered a hazard (H) in Saint Paul, and they're a suggested correction (SC) in Minneapolis.

How to fix a missing twist-out at the front of a panel

First, determine the brand and type of panel. It will probably say so right on the door. If it helps, take a photo of the label. Next, go buy some filler plates at a home improvement store or hardware store. You'll find them next to the circuit breakers.

(The Minnesota Star Tribune)

Finally, shut off the power to the panel and pop the appropriate filler in to place. This can typically be done without even removing the cover. For Truth-in-Housing evaluations, openings in the front of an electric panel are required repair items in Minneapolis, Bloomington, Hopkins, Robbinsdale, and South Saint Paul. They're considered a hazard in Saint Paul.

Now go forth and fill your holes with impunity.

Author: Reuben Saltzman, Structure Tech Home Inspections