This blog post is a compilation of three blog posts written by Reuben, which originally appeared at the moisture testing web site www.PrivateEyeMN.com.
Moisture testing on relatively newer stucco houses (mid 1980s - late 2000s) has become standard practice when buying a home in Minnesota, and a lot of those tests reveal problems with moisture intrusion. Water intrusion is never good news, but there are several options to consider when exploring a repair strategy for a home with water damage.
Remediation protocols range from retrofit, which consists of partial repair and maintenance, to full tear off and replacement, which consists of removing all of the stucco and replacing with an alternate cladding material, such as James Hardie HardiePlank® or LP Smartside®.
Today we'll be taking a closer look at all three repair strategies, all of which were performed by Sunset Construction Group (SunsetCG), a Minnesota company that specializes in repairing stucco houses with moisture intrusion problems.
When SunsetCG is contacted to perform stucco repairs on an existing home, there are four basic steps that take place; a review of the moisture testing report, removal of the stucco at the affected areas, repair of the affected areas, and maintenance on the rest of the stucco.
Case Study #1: Retrofit Repair
Review the Moisture Testing Report
The first thing SunsetCG wants to see is the moisture testing report, which is what we provide. This report will contain photos of the home along with moisture readings, which helps to determine the scope of the work and offers professional guidance to the buyer and sellers of a property. From there, a bid is put together on stucco repairs and various repair strategies are explored.
Reviewing this retrofit-level case study, we first performed moisture testing at this home in 2006, and found several areas with high moisture levels, but no repairs were conducted at that time. We performed moisture testing again in 2013, and many of those same areas showed high levels of moisture, so SunsetCG was contacted to perform repairs.
Here's an excerpt from our moisture testing report, showing exactly which areas of the wall sheathing had elevated moisture levels; our results from 2006 and 2013 are documented right next to each other on the report for comparison.